Mobile QR Code QR CODE
Export citation EndNote
Title Effect of Beam-Column Joint Model on the Seismic Performance Evaluation for Non-Seismic Designed RC Frame
Authors 이영욱(Young-Wook Lee) ; 한창훈(Chang-Hun Han)
DOI https://doi.org/10.4334/JKCI.2021.33.1.083
Page pp.83-93
ISSN 1229-5515
Keywords 보-기둥 접합부; 해석모델; 내진성능; 비내진설계된 철근콘크리트 골조 beam-column joint; analysis model; seismic performance; non-seismic designed RC frame
Abstract To study the influence of one analytical model of beam-column joint on the seismic performance evaluation for non-seismic designed RC buildings prior to 2005, push-over analyses were executed with the beam-column joint models based on FEMA 356 and NZ seismic assessment; results were compared with the case of no-joint model. For comparison, 2 and 4 story buildings were designed only for gravity loads, based on design codes in 1999. Basic seismic load was selected as 0.2 g multiplied with 2/3. Push-over analyses were performed and the performance points were obtained in case that the building importance factors were 1.0 and 1.2. At one performance point, the exterior joints reached plastic hinge state which was over the collapse prevention state, even though the required story drift ratio was satisfied. It was shown that the plastic deformation of FEMA model was greater than the result of NZ model when importance factor was 1.2, even though the shear strength of FEMA was greater than NZ model.