Mobile QR Code QR CODE
Export citation EndNote
Title Seismic Performance Evaluation of Seismic Strengthening Method using SRCF External Connection of Medium and Low-rise R/C Buildings
Authors 이강석(Kang-Seok Lee) ; 정주성(Jue-Seong Jung) ; 이종권(Jong-Kweon Lee)
DOI http://dx.doi.org/10.4334/JKCI.2015.27.2.147
Page pp.147-155
ISSN 1229-5515
Keywords SRCF ; 내진보강 ; 철근콘크리트 ; 유사동적실험 ; 중저층 ; 외부접합형 SRCF, seismic strengthening ; reinforced concrete ; pseudo-dynamic test ; medium-and low-rise ; external connection method
Abstract A new SRCF (Steel Reinforced Concrete Frame) external connection method for seismic strengthening of mediumand low-rise reinforced concrete buildings is reported in this paper. The SRCF method, proposed in this study, is capable of carrying out the seismic retrofitting construction while residents can live inside building. The method is one of the strength design approach by retrofit which can easily increase the ultimate lateral load capacity of concrete buildings controlled by shear. The pseudo-dynamic test, designed using a existing school building in Korea, was carried out in order to verify the seismic strengthening effects of the proposed method in terms of the maximum load carrying capacity and deformation. Test results revealed that the proposed SRCF strengthening method installed in RC frame enhanced conspicuously the strength and deformation capacities, and the method can resist markedly under the large scaled earthquake intensity level.