Mobile QR Code QR CODE
Export citation EndNote
Title Evaluation on the Shear Performance of U-type Precast Prestressed Beams
Authors 유승룡
Page pp.10-17
ISSN 1229-5515
Keywords U형; 광폭 보; 전단경간; 슬립; 정착부착; 정착길이; 파괴거동; U-type; wide barn; shear span; development length; failure pattern
Abstract Shear tests were performed on four ends of full scale U-type beams which were designed by optimum process for the depth with a live load of 4903Pa. The ratio of width to depth of full scale 10.5 m-span, composite U-type beams with topping concrete was greater than 2. Following conclusions were obtained from the evaluation on the shear performance of these precast prestressed beams. 1) Those composite U-type beams performed homogeneously up to the failure load, and conformed to ACI Strength design methods in shear and flexural behaviors. 2) The anchorage requirements on development length of strand In the ACI Provisions preyed to be a standard to determine a failure pattern within the limited test results of the shallow U-type beams. 3) Those all shear crackings developed from the end of the beams did not lead to anchorage failure. However, initiated strand slip may leads the bond failure by increasing the size of diagonal shear crackings. 4) The flexural mild reinforcement around the vertical center of beam section was effective for developments of a ductile failure.