Mobile QR Code QR CODE
Export citation EndNote
Title Setting Assessment of Hogh Strength Concrete Using the Ultrasonic Pulse Velocity Monitoring
Authors 이회근 ; 이광명
Page pp.973-981
ISSN 1229-5515
Keywords 고강도 콘크리트; 응결 시간; 초음파 속도; 관입 저항; 플라이 애쉬; high strength concrete; setting time; ultrasonic pulse velocity; penetration resistance; fly ash
Abstract Recently, the use of high strength concrete (HSC) has increased dramatically md however, few studies have been conducted on the early-age properties of HSC such as setting. The penetration resistance test (specified by KS F 2436) that is the standard test method for determining initial and final setting times of concrete, may not be appropriate for HSC because of the high viscosity of the mortar mixture. To address this issue, an ultrasonic pulse velocity (UPV) monitoring system was used to investigate the setting behavior of mortar and concrete. The experimental study was carried out to measure the UPV's of mortars and concretes having various water/binder ratios (W/B) and various fly ash replacement levels, during the first 24 hours of testing. Test results showed that the UPV in concrete was developed faster than that of mortar with the same W/B, and that of ordinary concrete was greater than that of fly ash concrete. Typical values of UPV were suggested that correspond to the initial and final setting times, based on following criteria: (1) the penetration resistance method; (2) the instant when the UPV begins to develop; and (3) the instant when the UPV development rate is maximum. The method and UPV monitoring device used in this study is promising for the setting assessment of concrete, particularly for HSC.