Mobile QR Code QR CODE
Export citation EndNote
Title Flexural Test on Composite Deck Slab Produced with Extruded ECC Panel
Authors 조창근 ; 한병찬 ; 이정한 ; 김윤용
Page pp.695-702
ISSN 1229-5515
Keywords ECC ; 압출성형패널 ; 복합바닥슬래브 ; 휨 실험 ; 균열제어 ECC ; extruded panel ; composite deck slab ; flexural experiments ; crack control
Abstract This paper presents a reinforced concrete composite deck slab system newly developed using a high ductile ECC extrusion panel. In the construction practice, the cracking of reinforced concrete slab often becomes a problem especially in parking garages, underground structures, and buildings. The ECC panel manufactured by extrusion process as a precast product has not only a high-quality in control of cracking but also a merit in applying the construction of concrete slab because the use of ECC panel can realize a formless or half-precast construction with cast-in-place concrete. In the newly developed deck slab system, the ECC extrusion panel is located in the bottom of slab with the thickness of 10 mm, reinforcements are assembled and located on the ECC panel, and finally the topping concrete is placed in the field. In order to evaluate the newly developed slab system, experimental works by four point bending test are conducted to compare with the conventional reinforced concrete slab system. From experiment, the developed deck slab system using a ECC panel gives many improved performances both in control of bending cracking and in load-carrying capacities of slabs.