Mobile QR Code QR CODE
Export citation EndNote
Authors 최재진 ; 김은겸 ; 유정훈
Page pp.473-480
ISSN 1229-5515
Keywords self compacting concrete; ground granulated blast furnace slag; mixture proportion
Abstract In this study, a mix design for self compacting concrete was based on Okamura's method and concrete incorporated just a ground granulated blast furnace slag. Replacement ratio of slag is in the range of 20~80% of cement matrix by volume. For the optimal self compactability in mixture incorporating ground granulated blast furnace slag, the paste and mortar tests were first completed. Then the slump flow, elapsed time of 500mm slump flow, V funnel time and filling height by U type box were conducted in concrete. The volume of coarse aggregate in self compacting concrete was in the range of 50~60% to the solid volume percentage of coarse aggregate. Finally, the compressive and splitting tensile strengths were determined in the hardened self compacting concrete incorporating ground granulated blast furnace slag. From the test results, it is desirable for self compacting concrete that the replacement of ground granulated blast furnace slag is in the range of 40~60% of cement matrix by volume and the volume of coarse aggregate to the solid volume percentage of coarse aggregate with a limit of 55%.