Mobile QR Code QR CODE
Export citation EndNote
Title Comparative Evaluation on Strength of Several Grout-filled Splice Sleeve
Authors 김형기
Page pp.635-644
ISSN 1229-5515
Keywords 그라우트 충전식 철근이음 ; 내력 ; 그라우트 압축강도 ; 철근의 정착길이 ; 슬리브 형상 grout-filled splice sleeve ; strength ; compressive strength of grout ; embedment length ; sleeve geometry
Abstract In this study, the tensile strength of 321 full-sized grout-filled splice steeve specimens were compared and analyzed in order to afford the data for a reasonable and economical design of this system. The experimental variables analyzed in this study were embedment length of reinforcing bars, compressive strength of grout, sleeve geometry, loading pattern and final failure mode of specimen. Following main conclusions are obtained : 1) The strength of grout-filled splice sleeve tends to be improved with increasing compressive strength of grout and embedment length of reinforcing bars. Specially this tendency appears apparent in specimens of bond failure rather than rebar failure. 2) The results of this study show that the sleeve geometry have influence on the bond strength of grout-filled splice sleeve. 3) The grout-filled splice sleeve of bond failure don't show the difference of tensile strength according to size of rebar. 4) It is verified that the tensile strength required in ACI and domestic code is retained either when the compressive strength of grout over 70 MPa is used with embedment length of reinforcing bars over 4.5d or when the compressive strength of grout over 80 MPa is used with embedment length of rebars over 3.9d. 5) It is verified that the tensile strength required in AIJ code is retained in case when the embedment length of reinforcing bars is 0.8 times the rebar diameter longer than in ACI code.