Mobile QR Code QR CODE
Export citation EndNote
Title Fire Test of Fiber Cocktail Reinforced High Strength Concrete Columns with Loading
Authors 염광수 ; 전현규 ; 김흥열
Page pp.473-480
ISSN 1229-5515
Keywords 섬유혼입공법 ; 재하 내화시험 ; 온도구배 ; 폭렬 fiber cocktail method ; fire test with loading ; temperature gradient ; explosive spalling
Abstract The 180 minutes fire test based on the standard curve of ISO-834 were conducted on three RC column specimens with different constant axial loading ratios to evaluate the fire performance of fiber cocktail (polypropylene+steel fiber) reinforced high strength concrete column. The columns were tested under three loading levels as 40%, 50%, and 61% of the design load. No explosive spalling has been observed and the original color of specimen surface has been changed to light pinkish grey. The maximum axial displacements of three specimens were 1.5~2.2 mm. There was no reduction in load bearing capacity of each specimen exposed to fire and no effect were observed on the fire performance within 61% of the design load. The tendencies of the results with loading, such as the temperature distribution of in concrete and the changes in temperature rise due to the water vaporization in concrete, are very similar to those without loading. The final temperatures of steel rebar after 180 minutes of fire test resulted in 491.4oC for corner rebar, 329.0oC for center rebar, and 409.8oC for total mean of steel rebar. The difference of mean temperature between corner and center rebar was 153.7oC. The tendency of temperature rise in concrete and steel rebar changed after 30~50 minutes from the starting time of the fire test because the heat energy influx into corner rebar is larger than that into center rebar. The cause of decrease in temperature rise was due to the water vaporization in concrete, the lower temperature gradient of the concrete with steel and polypropylene fiber cocktails, the moisture movement toward steel rebars and the moisture clogging.