Mobile QR Code QR CODE
Export citation EndNote
Title Fire Resistance Performance for Hybrid Fiber Reinforced High Strength Concrete Column Member
Authors 원종필 ; 장창일 ; 이상우 ; 김흥열 ; 김완영
Page pp.827-832
ISSN 1229-5515
Keywords 화재저항성 ; 고강도 기둥부재 ; 폴리프로필렌(PP) 섬유 ; 강섬유 fire resistance ; high strength column ; polypropylene fiber ; steel fiber
Abstract This study evaluated fire resistance performance for hybrid (polypropylene + steel) fiber reinforced high strength concrete column. Full-size columns were constructed and tested with or without fibers using ISO-834 fire curve. As the result of test, Control specimen occurred serious spalling and indicated rapidly internal temperature increasing. Specimen with polypropylene fiber occurred not spalling but steady internal temperature increasing. Specimen with hybrid fiber occurred not spalling as well as does not propagated temperature distribution. Therefore, hybrid fiber reinforced column specimen indicated a good fire resistance performance than other cases.