Mobile QR Code QR CODE
Export citation EndNote
Title Spalling and Internal Temperature Distribution of High Strength Column Member with Polypropylene Fiber Volume Fractions
Authors 원종필 ; 장창일 ; 김흥열 ; 김완영
Page pp.821-826
ISSN 1229-5515
Keywords 화재저항성 ; 고강도 기둥부재 ; 폴리프로필렌(PP) 섬유 fire resistance ; high strength column ; polypropylene fiber
Abstract This study evaluated spalling and internal temperature distribution after elevated temperatures test for high strength concrete ( fck = 60 MPa) column member with various polypropylene fiber volume fractions. The ISO-834 time-temperature curve was used for measurement of fire resistance properties. As the result of test, average internal temperature results indicated to low temperature in increased polypropylene fiber volume fraction. But, the highest internal temperature results show that does not difference in proportion of polypropylene fiber volume fractions.