Mobile QR Code QR CODE
Export citation EndNote
Title Evaluation on the Behaviors of Precast Concrete Beam-Column Commections for Apartments
Authors 송형수 ; 유승룡
Page pp.657-666
ISSN 1229-5515
Keywords 프리캐스트 콘크리트 ; 보-기둥 연결부 ; DDC 연결부 ; 반복하중
Abstract The precast concrete beam-column connectors to retrofit an apartment building were investigated experimentally. Five precast concrete beam-column connectors were considered to develop a modified model which was adapted to domestic construction conditions from the DDC(dywidag ductile connection) of Germany. Special H-shape steel hardware was used to decrease the width of column and beams for the construction of external frames in apartments. It was found that the DDC had high joint strength and ductility, however failed in inclined shear crackings in the columns. The modified one showed better behaviors in tests because they did not show critical column crackings at failure. The test result of modified one with grouting was compared to that of the one without grouting within the duct. The one with grouting showed higher strength and ductility in failure than that without grouting.