Mobile QR Code QR CODE
Export citation EndNote
Authors 송한범 ; 이원호
Page pp.1001-1010
ISSN 1229-5515
Keywords 병렬 전단벽 시스템 ; 커플링보 ; 연성 ; 지압판 coupled shear wall system ; coupling beam ; ductility ; face bearing plate
Abstract The usefulness of walls in the structural planning of multistory buildings has long been recognized. When walls are situated in advantageous positions in a buildings, they can be very efficient in resisting lateral load. Specially coupled shear wall system is the primary lateral load resisting system of buildings. It is customary to refer to such walls as being 'coupled' by coupling beams. The coupling beams must exhibit excellent strength, stiffness ductility and energy dissipation capacity. To achieve these demands for steel coupling beam, steel coupling beam with Face Bearing Plate(FBP) embedded in the reinforced concrete walls is proposed. A comprehensive experimental test involving 2 steel coupling beam with and without FBP has been performed. Through experimental study, the evaluation of the advantage of that was establish and proposed the failure mode.